Features

No. 1

Features dense, low-footprint GE aggregation in a non-blocking, wire-speed architecture with 20 100M/1GbE SFP ports and 4 1GbE/10GbE multi-rate SFP+ ports

No. 2

Offers dual AC or DC power in a high availability, temperature-hardened, 1RU package

No. 3

Supports Zero-Touch Provisioning to minimize OPEX and accelerate service turn-up while providing a service ‘birth certificate’ with built-in service activation testing

No. 4

Complies with MEF CE2.0 specifications for E-Line, E-LAN, E-Tree, and E-Access services

No. 5

Incorporates flexible transport options, including G.8032 rings, 802.1q VLANs, 802.1ad Provider VLANs (Q-in-Q), IP/MPLS, MPLS-TP, and PBB-TE

No. 6

Includes on-board, line-rate performance benchmark testing capabilities for end-to-end SLA verification

5142 Visio stencil

Download stencil

Specs

  • +Interfaces
    • 4 x 1/10G SFP+ ports
    • 20 x 100/1000M SFP port
    • 1 x 10/100/1000M RJ-45 Management Port
    • 1 x Console Port (RJ-45, EIA-561)
    • 16 x External Alarm Inputs
    • 1 x RJ-45 sync input/output port
    • 2 x SMB sync input/output ports
  • +Ethernet
    • IEEE 802.3 Ethernet
    • IEEE 802.3u 100Base-TX via copper SFP
    • IEEE 802.3z Gigabit Ethernet
    • IEEE 802.3-2008 10-Gigabit Ethernet
    • IEEE 802.1D MAC Bridges
    • IEEE 802.1Q VLANs - Including .1p Priority
    • IEEE 802.1ad Provider Bridging (Q-in-Q) VLAN full S-VLAN range
    • VLAN tunneling (Q-in-Q) for Transparent LAN Services (TLS)
    • Per-VLAN MAC Learning Control
    • Per-Port MAC Learning Control
    • Rapid / Multiple Spanning Tree (RSTP/MSTP)
    • IEEE 802.3ad Link Aggregation Control
    • Protocol (LACP)
    • ITU-T G.8032 Ethernet Rings Protection Switching
    • Jumbo Frames to 9216 bytes
    • Layer 2 Control Frame Tunneling
    • Private Forwarding Groups
    • MEF CE 2.0 Compliant
      • E-LINE: EPL, EVPL
      • E-LAN: EP-LAN, EVP-LAN
      • E-Access: Access EPL, Access EVPL
      • E-Tree: EP-Tree, EVP-Tree
  • +Carrier Ethernet OAM
    • IEEE 802.1ag Connectivity Fault Management (CFM)
    • IEEE 802.3ah Ethernet in the First Mile (EFM)
    • IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
    • ITU-T Y.1731 Performance Monitoring
    • RFC 2544 Performance Benchmarking Test
    • Generation and Reflection up to 1GE
    • ITU-T Y.1564 Ethernet Service Activation Test Methodology
    • RFC 5618 TWAMP Responder and Receiver
    • TWAMP Sender
    • TWAMP +/- 1ms timestamp accuracy
    • Dying Gasp with Syslog and SNMP Traps
  • +Quality of Service
    • 8 Hardware Queues per Port
    • Committed, Excess Information Rate (CIR, EIR)
    • Classification based on
    • IEEE 802.1D priority
    • VLAN, source port, destination port
    • IP Precedence and IPDSCP
    • Layer 2, 3, 4 Quality of Service
    • Ingress metering per-port
    • Ingress metering per-port per-CoS
    • Ingress metering per-port per-VLAN
    • Up to 8000 Ingress Meters per-port
    • Up to 8000 Ingress Meters per-system
    • C-VLAN Priority to S-VLAN Priority Mapping
    • S-VLAN Priority based on C-VLAN ID Per-VLAN Classification, Metering, and Statistics
    • Per-port, per-VLAN QoS with CIR and EIR traffic on Egress Queues
  • +Synchronization
    • ITU-T G.8262/G.8264 EEC option1 and option2
    • ITU-T G.781
    • IEEE 1588v2 (OC & BC*)
    • ITU-T G.8261
    • ITU-T G.8265/G8265.1
    • ITU-T G.8271
    • ITU-T G.8275/G.8275.1/G.8275.2
    • ITU-T G.823/G.824
    • ITU-T G.813
    • GR-1244
    • Stratum3E oscillator
    • External Timing Interfaces
      • BITS in or out (1.544MHz, 2.048MHz, 2Mbps, 64kcc/6312kcc)
      • 10MHz,1.544MHz, 2.048MHz in or out
      • GPS 1pps in or out
      • ToD in or out (NMEA 0183, MSTS)
  • +MPLS/VPLS/MPLS-TP
    • RFC 2205, 3031, 3036, 3985 MPLS Pseudowire Emulation Edge-to-Edge (PWE3)
    • RFC 5654 MPLS-Transport Profile (TP)
    • LSP Static provisioning
    • 1:1 Tunnel protection
    • LSP BFD via Gal/Gach
    • MPLS Virtual Private Wire Service (VPWS)
    • RFC 4762 VPLS (Virtual Private LAN Service) and Hierarchical VPLS (H-VPLS)
    • Provider Edge (PE-s) Functionality for VPLS and H-VPLS
    • VPLS with multiple VPLS Mesh Virtual Circuits
    • H-VPLS with Hub and Spoke Virtual Circuits
    • MTU-s Functionality for H-VPLS deployment
    • MTU-s Multihoming (redundant VCs to different PE-s switches)
    • MPLS Virtual Circuit as H-VPLS spoke Virtual Circuit
    • PBB-TE Service Instance as H-VPLS spoke Virtual Circuit
    • Q-in-Q Ethernet Virtual Circuit as H-VPLS spoke Virtual Circuit
    • MPLS Label Switch Path (LSP) Tunnel Groups MPLS Label Switch Path (LSP) Tunnel Redundancy
    • Layer 2 Control Frame Tunneling over MPLS Virtual Circuits
    • RFC 3209 RSVP-TE (for MPLS Tunnel Signaling)
    • RFC 3630 OSPF-TE (for MPLS Tunnel Routes)
    • RFC 3784 IS-IS-TE (for MPLS Tunnel Routes)
    • RFC 3036 LDP & Targeted LDP (for VPLS VC signaling)
    • RFC 4090 MPLS Fast ReRoute signaling
    • LSP Ping & Traceroute
  • +PBB-TE (Provider Backbone Bridging-Traffic Engineering)
    • IEEE 802.1Qay PBB-TE
    • IEEE 802.1ah PBB frame format
    • PBB-TE Multi-homed Protection Failover
    • IEEE 802.1ag CFM for PBB-TE Tunnels
    • IEEE 802.1ag CFM for PBB-TE Service Interfaces
    • PBB-TE Full B-VID & I-SID address ranges
    • PBB-TE Tunnel & Service metering
  • +Multicast Management
    • RFC 2236 IGMPv2 Snooping
    • IGMP Domains
    • IGMP Message Filtering
    • IGMP Inquisitive Leave
    • Broadcast/Multicast Storm Control
    • Unknown Multicast Filtering
    • Well-known Protocol Forwarding
  • +Network Management
    • Enhanced CLI
    • CLI-based configuration files
    • SNMP v1/v2c/v3
    • SNMPv3 Authentication and Message Encryption
    • RFC 1213 SNMP MIB II
    • RFC 1493 Bridge MIB
    • RFC 1643 Ethernet-like Interface MIB
    • RFC 1573 MIB II interfaces
    • RFC 1757 RMON MIB - including persistent configuration
    • RFC 2021 RMON II and RMON Statistics
    • Per-VLAN Statistics
    • RADIUS Client and RADIUS Authentication
    • TACACS + AAA
    • RFC 2131 DHCP Client
    • RFC 1305 NTP Client
    • RFC 1035 DNS Client
    • Telnet Server
    • RFC 1350 Trivial File Transfer Protocol (TFTP)
    • RFC 959 File Transfer Protocol (FTP)
    • Secure File Transfer Protocol (SFTP)
    • Secure Shell (SSHv2)
    • Syslog with Syslog Accounting
    • Port State Mirroring
    • Virtual Link Loss Indication/Remote Link Loss Forwarding (VLLI/RLLF)
    • Dual-Stack IPv4/IPv6 management plane
    • Local Console Port
    • Comprehensive Management via Ethernet Services Manager
    • Remote Autoconfiguration via TFTP, SFTP
    • Software download/upgrade via TFTP, SFTP
  • +Service Security
    • Common Criteria EAL2 compliant and certified
    • Egress Port Restriction
    • IEEE 802.1X Port-Based Network Access Control (RADIUS/MD5)
    • Layer 2, 3, 4 Protocol Filtering
    • Broadcast Containment
    • User Access Rights
    • Per-port or per-VLAN Service Access Control
    • Hardware-based DOS Attack Prevention
  • +MAC Address Table Capacity
    • 128,000 MAC addresses
  • +Power Requirements
    • DC Input: -48,-/+36, -/+24 VDC (nominal)
    • AC Input: 100V, 240V AC (nominal)
    • AC Frequency: 50/60 Hz
    • Maximum Power Input: 150 W
  • +Agency Approvals
    • Agency Marks:
      • NRTL (Canadian Standards Association)
      • CE mark (European Union)
        • EMC Directive (2004/108/EC)
        • LVD Directive (206/95/EC)
        • RoHS2 Directive (2011/65/EU)
      • Australia C-Tick (Australia/New Zealand)
      • VCCI (Japan)
    • Emissions:
      • FCC Part 15 Class A
      • Industry Canada ICES-003 Class A
      • VCCI Class A
      • CISPR 22 Class A
      • GR-1089 Issue 6
      • EN 55022
    • Immunity (EMC):
      • CISPR 24
      • EN 55024
      • GR-1089 Issue 6
      • EN 300 386
    • Power:
      • ETSI EN 300 132
    • Safety:
      • EN 60950-1
      • CAN/CSA C22.2 No. 60950-1-07
      • UL 60950-1 2nd Ed
    • Environmental:
      • RoHS Directive (2011/65/EU)
      • WEEE 2002/96/EC
  • +Environmental Characteristics
    • GR-63-CORE, Issue 4 – NEBS Level 3
    • GR-1089 Issue 6 – NEBS Level 3
    • GR-3108 Issue 2 Network Equipment in the Outside Plant (OSP) Class 2
    • ETSI 300 019 Class 1.2, 2.2, 3.2
    • Operating Temperature:
      • -40°F to +149°F (-40°C to +65°C)
    • Storage Temperature:
      • -40°F to +158°F (-40°C to +70°C)
    • Relative Humidity:
      • 5% to 90% (non-condensing)
  • +Physical Characteristics
    • Dimensions:
      • 17.5” (W) x 9.9” (D) x 1.75“(H);
      • 444mm (W) x 252mm (D) x 44mm (H)
    • Weight:
      • 12.8 lbs; 5.8kg (incl. 2 DC PSU’s)

3D Product View

Questions? Ask the community.

Ask

Want to know more about the 5142? Let's talk.

Contact us